Apps
Food Industry
Sanitary Applications
Bio & Pharmaceutical Industry
Container with automatic cleaning device
Suitable for mixing and mixing containers
Features
No dead zone
Sanitary design
Materials and surface treatment quality are in line with hygienic design standards
Materials and surface treatment quality are in line with the pharmaceutical industry directives and standards
Plane measurement, non-corrosive substance
Description
TR20 type thermal resistance thermometer is suitable for temperature measurement in sanitary applications.
This model is equipped with a NEUMO BioControl® flushing fitting, especially for applications where it is not possible or necessary to immerse the sheath in the process media. If the user has higher hygiene requirements for components in contact with the surrounding environment, a stainless steel fitting that optimizes the hygienic design can be selected.
TR20 combined with block flange (small section design), especially suitable for temperature measurement in mixing and mixing containers (with automatic cleaning device). Finally, a measuring instrument mounted flush on the wall of the container can be realized. The process medium can be easily removed from the inner wall by rotating the cleaning device. This not only enables uniform mixing of the material, but also enables accurate temperature measurement in the mixing vessel.